Iec 60352-2 Pdf __hot__
Failure occurs if wire pulls out before reaching minimum force, or if wire breaks at crimp edge (unless break force > minimum).
| Wire cross-section | Max allowable contact resistance (milliohms) | |-------------------|-----------------------------------------------| | 0.05 – 0.5 mm² | 3 mΩ | | 0.5 – 1.5 mm² | 2 mΩ | | 1.5 – 10 mm² | 1 mΩ | iec 60352-2 pdf
Includes tests for tensile strength (pull-out force), bending, and vibration endurance. Failure occurs if wire pulls out before reaching
Validates performance under rapid temperature changes, dry heat, damp heat cycles, and corrosive gas environments. damp heat cycles
Some national bodies offer access via subscription (e.g., IEC National Committee members).